Top > OPERATION > Using Wireless Remote Control > Using the I-Control Ampere Function (Optional)

Using the I-Control Ampere Function (Optional)

  • Turn the appliance on.

  • Press Ampere Ctrl. button.

    • Press Ampere Ctrl. button repeatedly to select each step.

Note
  • 1 step : The power input is setting around 8 A to operate the appliance.

    • ^8A is displayed on the display screen.

  • 2 step : The power input is setting around 6 A to operate the appliance.

    • ^6A is displayed on the display screen.

  • 3 step (Optional) : The power input is setting around 4 A to operate the appliance.

    • ^4A is displayed on the display screen.

  • ^ will be blinking on the indoor unit, when the air conditioner needs more Ampere for operating than setting ampere’s operation range.

    • If you change the step by pressing Ampere Ctrl. button, ^ blinking will be disappeared.

  • This function is available with Cooling Mode.

  • Capacity may decrease when I-Control Ampere mode is selected.

  • Desired temperature is displayed about 5 seconds if you press Fan Speed, a or b button.

  • Room temperature is displayed about 5 seconds if you press Room Temp. button.

How to Use I-Control Ampere

Code

Range

When to Use

Ampere Ctrl. button

4 A

4 ~5.9 Ampere

Up to 46 7 (T3)

Click 3 times

6 A

6 ~ 7.9 Ampere

Up to 54 7 (T3)

Click 2 times

8 A

8 ~ 9.9 Ampere

Click 1 time

  • Above recommended figures are based on laboratory testing under following conditions:

    • Standard voltage (220V±15%)

    • Properly insulated room

    • Suitable A/C tonnage for room size

    • Correctly installed unit with R410A gas and vacuum work