Hood Fixing Bracket
Chimney Fixing Bracket
Screws (Φ4.2 mm x 9.5 mm)
Screws (Φ5 mm x 50 mm)
Wall Plugs
The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels.
Do not install the range hood near a heat producing appliance for solid fuel (e.g. wood or coal) unless a closed, nonremovable cover is available. There must be no flying sparks.
Make sure that there are no electrical lines, water lines or other utilities in the drilling area before drilling.
A vertical line up to the ceiling or up to the upper limit, at the center of the area in which the range hood is to be fitted.
A horizontal line A at 1320 - 1700 mm above the cooker top.
A horizontal line B at a minimum 926 mm above the cooker top.
A horizontal line C at a minimum 730 mm above the cooker top.
Mark a point (1) on the horizontal line A, 60 mm to the right of the vertical reference line.
Repeat this operation on the other side, checking that the two marks are leveled.
Mark a point (2) on the horizontal line B, 80 mm to the right of the vertical reference line.
Repeat this operation on the other side and on the vertical reference line, checking that the three marks are leveled.
Mark a point (3) on the horizontal line C, 130 mm to the right of the vertical reference line.
Repeat this operation on the other side, checking that the two marks are on the same horizontal line.
Drill at the marked points (1) (2) (3), using a Φ10 mm drill bit.
Insert the wall plugs e into the holes (1) (2) (3).
Fix the hood fixing bracket a with 3 screws (Φ5 mm x 50 mm) d supplied with the range hood at the points (2).
Fix a chimney fixing bracket b with 2 screws (Φ5 mm x 50 mm) d supplied with the range hood at the points (1).
The range hood can be operated in recirculation or extraction-air mode. Extraction-air mode, the air is discharged out of the house by a pipe. Recirculation mode, the air is purified and discharged into the house through two rows of holes on the adjustable decorative chimney. For recirculation mode, assembled activated charcoal filters on each side as cover to both the shield grids of the motor impeller, then turn clockwise a. For the disassembly, turn counterclockwise b
For recirculation mode, without the exhaust pipe, install activated charcoal filters. When activated charcoal filters attached, the suction power will be lowered.
Remove the protective film from the decorative chimney and hood body.
Open the panel.
Remove all metal grease filter using the handles provided. See MAINTENANCE chapter.
Hook the hood body to the hood fixing bracket a.
From the inside of the hood body, fix the screws (Φ5 mm x 50 mm) d to wall plugs e at the points (3).
Connect the power cord.
Fit the grease filter into the range hood.
Close the panel.
Hook the mounting brackets h onto the hood body, and fix them with 2 screws c (Φ4.2 mm x 9.5 mm), making sure that they are well seated.
i Move the mounting bracket along the direction shown in the figure.
Fix a chimney fixing bracket b onto the lower decorative chimney with 2 screws (Φ4.2 mm x 9.5 mm) c supplied with the appliance.
Slightly widen the two sides of the lower chimney and hook them to the brackets h, fix the lower chimney onto the mounting brackets h with 2 screws c (Φ4.2 mm x 9.5 mm) supplied with the appliance. Take care not to pinch the power cord.
Fix the exhaust pipe in position using tapes. When installing the ducted version, connect the appliance to the chimney using either a flexible or rigid pipe Φ150 mm, the choice of which is left to the installer.
Slightly widen the two sides of the upper chimney and hook them between the wall and the chimney fixing bracket b which is fixed on the lower decorative chimney.
Fix the upper chimney onto the chimney fixing bracket b at the wall with 2 screws (Φ4.2 mm x 9.5 mm) c supplied with the appliance.