Top > INSTALLATION > Test Run > Test the Range Before Use

Test the Range Before Use

Automatic Ignition System

To check automatic ignition of the Bake burner, follow the steps below:

  • Remove all packing materials from inside the oven cavity.

  • Push in and turn the oven knob counterclockwise. You will hear a clicking sound indicating proper operation of the spark module.

  • Visually check that the oven burner has lit.

Manual Ignition System (In case of power failure)

To check manual ignition of the Bake burner, follow the steps below:

  • Remove all packing materials from inside the oven cavity.

  • Push in and turn the oven knob counterclockwise.

  • Hold a lighter flame or a lit match to the hole located in the oven bottom.

  • Visually check that the oven burner has lit.

General Nozzle Table

  • LP Gas Specifications

    Burner

    Gas Pressure (kPa)

    Thermal Capacity (MJ/h)

    Nozzle No. (1/100 mm)

    Rapid

    2,9

    9,900

    85

    Semi-Rapid

    2,9

    5,940

    65

    Oven

    2,9

    15,120

    102

    Note
    • Each nozzle has a nozzle number a on the top or on the side, denoting the location on the range where it is to be installed.