The oven must be connected by a licensed specialist in accordance with these instructions and in compliance with local regulations. Make sure the voltage shown on the rating label is the same as the power supply voltage in your home.
The oven must be connected to the power supply by means of an all-pole disconnect switch with a minimum contact gap of 3 mm and must be connected to earthed socket by law. The supply disconnect (isolation) switch shall be accessible after the installation. The oven's components operate at 230 V / 50 Hz. Identify the phase and neutral conductor on the supply lead before making connection. Incorrect connection may damage the oven.
Connect the oven to the power supply.
Live
Neutral
Earth
Connect the green and yellow ground wire to the right terminal pole, the live brown or red wire to the left terminal pole, and the neutral blue or black wire to the center terminal pole.